Showing posts with label Lead Battery Recycling. Show all posts
Showing posts with label Lead Battery Recycling. Show all posts

Used Spent Lead Acid Batteries Management

Spent lead-acid batteries from automobiles contain lead and sulfuric acids and are fully regulated as a hazardous waste. However, when intact they can be managed for recycling, and the handling requirements are relaxed. Generators of lead-acid batteries include auto repair shops, parts stores and service stations, as well as other businesses and factories that generate dead or damaged batteries. Businesses must take care in the way that they store batteries prior to shipment to a recycler, as follows.

STORAGE REQUIREMENTS
Undamaged batteries should be stored upright on a covered pallet over a non-reactive, curbed and sealed surface such as coated concrete or asphalt, and care should be taken to prevent the terminals from short-circuiting.

Damaged batteries are batteries that are cracked, broken, or missing one or more caps. The business must store and transport damaged batteries in non-reactive, structurally-secure, closed containers such as polyethylene buckets or drums. If missing caps can be replaced and there are no other leaks or damage, the battery can be managed along with intact batteries.

ACCUMULATION REQUIREMENTS
Businesses must label containers holding damaged batteries in ink or paint with the date the first battery was placed there. This is considered the accumulation start date. There are no labeling requirements for undamaged batteries, but there are associated accumulation time limits for both damaged and undamaged batteries, as follows:
• Businesses that have less than one ton of batteries may store the batteries on site for no more than one year.
• Businesses that have more than one ton of batteries may not store them longer than 180 days.
If these quantities or times are exceeded, the business is no longer exempt from the regulations for generation, storage and transportation of hazardous waste.

TRANSPORTATION REQUIREMENTS
If a business ships more than 10 batteries at a time, a legible hazardous waste manifest or a legible bill of lading must accompany the shipment. The generator, transporter and storage, recycling, or disposal facility each must retain their copies of either of those documents for three years. The bill of lading must be dated and show the name and addresses of the generator, transporter, and receiving location, as well as the number of batteries transported. The business may transport damaged batteries (packaged as described above) with intact batteries, as long as all Department of Transportation (DOT) standards are met.

RECORD KEEPING REQUIREMENTS
Businesses generating or handling more than 10 batteries per year and those who transport more than 10 batteries at a time are required to keep all copies of bills of lading and manifests related to the transportation of lead-acid batteries for a period of at least three years.

Businesses generating no more than 10 batteries per year, and storing or transporting no more than 10 batteries at one time, are not subject to the reporting and record keeping, requirements given in the battery regulations as long as the batteries will go to someone who stores, recycles, uses, reuses or reclaims them. This also applies to people who trade in an old battery for a new one and to the person accepting the trade-in. All businesses, however, must comply with storage and accumulation requirements given in the battery regulations.

Disclaimer
This guidance document does not replace or supersede relevant statutes and regulations. It is intended for informational purposes only and may not encompass all of the statutes and regulations to this topic. More details may be found at Cal EPA Department of Toxic Substances Control (DTSC) www.dtsc.ca.gov

Recycle Scrap Lead Batteries and Contribute to save environment on World Environment Day

World Environment Day, June 05,2012. Contribute to Save your environment by recycling your old Lead acid batteries and junk accessories and things. Plant the trees and make the world greener and healthy.

Gravita Initiates to setup battery recycling plant in Trinidad & Tobago

Gravita India Limted has taken a strong move towards its global presence. Company has initiated to setup a new battery recycling plant in Trinidad & Tobago.


Mr. Rajat Agrawal (MD of GRAVITA) and Mr. Brian Frontin (The Chairman of InvesTT) has signed a memorandum of understanding (MOU)  in the presence of Mr. Stephen Cadiz (Minister of trade and Industry in Trinidad & Tobago).

Rotary Furnace for Lead Smelting

In most of the world other than the U.S., rotary furnaces (long, short, and top blown) have replaced blast furnaces as the major smelting vessels for lead recycling. Rotary furnaces are very versatile. They can accept virtually any type of lead-bearing feed material, including battery scrap, dust, dross, scrap lead, and sludge. Rotary furnaces can use any carbon source such as coal, coke, or ebonite as reducing agent, and they can use a variety of fuels, such as oil, coal, or gas. Because they are batch furnaces, rotary furnaces can be operated in stages to produce low-impurity bullion for refining to pure lead, or they can completely reduce the charge to recover all metal values for production of lead-antimony alloys. Rotary furnaces generally use Na2CO3 and iron as fluxes, which produce a fluid, low-melting slag.

Lead Battery Recycling Plant Supplier

Gravita Exim Ltd.- Leading Lead Battery Recycling Plant and technology supplier. We provide comprehensive solutions for waste batteries.

Key Features & Services
  • Secondary Lead Smelting Plants
  • Lead Refining, Alloying Techniques & Equipments
  • Lead Sub-Oxide, Red Lead & Litharge Manufacturing Plants
  • Pollution Control Systems for Lead Processing Industries
  • Technical Consultancy & Services for Lead Recycling & Smelting Operations
  • Training of Personnel for Lead Processing
  • Designing & Retrofitting of Existing Pollution Control Plant / Battery Recycling Plant
  • PLC based Control & Monitor System for advanced setups
  • Layout & Thorough Engineering design of the Plant
  • Supply of complete Plant & Machinery
  • Provide assistance and supervision of the Plant Erection
  • Commissioning of the Plant
  • Provide process information and Training to your personnel
  • Establish process and product quality
     
Call Us : +91-141-4057800 for further queries

Lead Battery Acid Handling

Great care should therefore be employed when removing acid by draining thecasing. Once it is collected, it is important that the acid be neutralised toincrease the pH (and hence reduce its corrosiveness) but also to remove thelead dissolved in the acid.

The acid should be diluted with an excess of water to give a 5 to 10-folddilution. The liquid should then be neutralized by mixing with an equal volumeof agricultural lime, or other alkaline material containing calcium carbonate, orsodium hydroxide. Use ofhydrated lime has the advantage of lower cost per unit of neutralizing capacitywhen compared to sodium hydroxide.

Coral rock may be an alternative in many PICs, although use of calciumcarbonate or sodium hydroxide is preferred. The coral rock to be used shouldbe dead coral, preferably washed ashore which can be crushed finely andadded to the liquid requiring neutralization. If the ro ck is to be used, it shouldbe crushed into very small particles to increase the surface area so that the neutralization reaction can proceed as fast as possible. If large particles areadded to the acid it may take a lot longer for the same neutralization level tobe reached.

After the additive has been mixed with the acid, universal paper is to be usedto test the resulting pH of the liquid. (Universal paper can be purchasedcheaply from chemical companies, again contact details are included later).Once the liquid has reached a pH of 7.5 it has been neutralised and is safe todischarge to the environment. It is important to ensure that the pH is withinthe range of pH 7-8, as outside of this range there will be levels of lead stilldissolved into solution.

To remove the lead precipitates after neutralization, the solution must then befiltered. Soil can be used as an appropriate filter medium. A column of soilcontained in a metal container ie. 44 gallon metal drum with each endremoved, may be suitable for this purpose. The liquid once drained throughthis filter is ready for release to the environment.

The soil should be regularly replaced if large quantities of battery acid is beingfiltered. It is crucial that the soil must be encapsulated by mixing with wetconcrete and can then be disposed to landfill as general waste. If the soil isnot mixed with concrete, the lead will leach through the soil and becomemobile in landfill leachate in high concentrations.

Another way to treat acid is to process it by reacting it with sodium hydroxideto convert it to sodium sulfate, an odorless white powder used in laundrydetergent, glass and textile manufacturing. This process takes a material thatwould be discarded and turns it into a useful product.

What waste lead batteries contain?

Lead acid batteries are made up of plates, Lead, and Lead oxide with a 35% sulfuric acid and 65% water electrolyte solution. Lead acid batteries represent almost 60% of all batteries sold worldwide.

Classification:
Generally there are two types of Lead-acid storage batteries, based on their method of construction Flooded or Sealed. Flooded (or wet) Lead acid batteries are those where the electrodes / plates are immersed in electrolyte. Sealed Lead acid or valve-regulated Lead acid (VRLA) battery where the electrolyte is immobilized. All Lead-acid batteries produce hydrogen and oxygen gas (gassing) at the electrodes during charging through a process called electrolysis. These gases are allowed to escape a flooded cell, however the sealed cell is constructed so that the gases are contained and recombined.

Lead Acid Battery waste Recycling
The grid structure in both batteries is made from a Lead alloy. A pure Lead grid structure is not strong enough & therefore other metals like antimony, calcium, tin, and selenium in small quantities are alloyed for added strength and improved electrical properties.
The electrolyte in a Lead-acid battery is a dilute solution of sulfuric acid (H2SO4). The negative electrode of a fully charged battery is composed of sponge Lead (Pb) and the positive electrode is composed of Lead dioxide (PbO). The separator is used to electrically isolate the positive and negative electrodes.

Waste Batteries:
The typical Lead-acid battery comprises of: metal grids, electrode paste, Sulphuric acid, connectors and poles of Lead alloy, and grid separators made up of PVC. The battery components are contained in corrosion and heat-resistant housing usually composed of plastic (polycarbonate, polypropylene, or polystyrene).

The composition of waste batteries include:Lead: 25-30%(alloy, components, (grids, poles))Electrode paste (fine particles of lead oxide and lead sulphate): 35-45%Sulphuric Acid 10% to 15%Polypropylene: 5-8%Other plastic (PVC, other plastic): 1-3%Other materials 0-5%
In the past, grids were mainly made from antimony Lead alloys, but new trends show an increase in the usage of calcium Lead alloys. The electrode paste of used batteries is a mixture of Lead sulphate and Lead oxide. The composition of typical battery scrap material is given in Table.

Drained Lead Acid Battery Scrap
Drained Lead Acid Battery Scrap shall consist of whole drained lead/acid batteries. May contain plastic or rubber cases, but may not contain wooden, metal or glass cases. Similar to ISRI code RAINS.
This is the most preferred type of raw material for Lead recyclers/smelters or recycling/smelting Industries. We provide Rotary based Smelting plants for processing such raw material with equipments & machines for handling & separation of Lead.

Recycle old batteries in Plants

Earth Day is April 22, but Gravita Exim will celebrate it for the whole month with its annual "Great Battery Roundup".

During April, Gravita Exim will accept scrap batteries and lead batteries at no cost; these used automotive or marine lead-acid batteries will be sent its plants where they can be recycled into new batteries and save the environment.

There are more than 9 Battery Recycling Plants of Gravita Exim all over the world that meet the criteria for Lead battery recycling.

Lead acid batteries are made up of plates, Lead, and Lead oxide with a 35% sulfuric acid and 65% water electrolyte solution. Lead acid batteries represent almost 60% of all batteries sold worldwide.

Car batteries contain about 18 pounds of lead and a pound of sulfuric acid, so they can be extremely hazardous and cause environmental contamination.

Battery Recycling Plant requires that the batteries be sorted according to chemistries. Some sorting must be done prior to the battery arriving at the recycling Plant. Nickel-cadmium, nickel-metal-hydride, lithium-ion and Lead acid are placed in designated boxes at the collection point.